一般特性: |
Detection type |
photoelectric sampling |
Device type |
Multiturn absolute encoder |
功能安全性參數(shù): |
MTTFd |
70 a |
Mission Time (TM) |
20 a |
L10h |
1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load |
Diagnostic Coverage (DC) |
0 % |
電氣特性: |
Operating voltage |
10 ... 30 V DC |
Current consumption |
max. 230 mA at 10 V DC, max. 100 mA at 24 V DC |
Time delay before availability |
< 1000 ms |
Linearity |
± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit |
Output code |
binary code |
Code course (counting direction) |
programmable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending) |
接口: |
Interface type |
PROFIBUS |
Resolution |
|
|
Single turn |
up to 16 Bit |
|
Multiturn |
14 Bit |
|
Overall resolution |
up to 30 Bit |
Transfer rate |
0.0096 ... 12 MBit/s |
Standard conformity |
PNO profile 3.062, RS-485 |
連接: |
Terminal compartment |
in removable housing cover |
符合標(biāo)準(zhǔn): |
Degree of protection |
DIN EN 60529,
shaft side: IP64 (without shaft seal)/IP66 (with shaft seal)
housing side: IP65 |
Climatic testing |
DIN EN 60068-2-3, no moisture condensation |
Emitted interference |
EN 61000-6-4:2007 |
Noise immunity |
EN 61000-6-2:2005 |
Shock resistance |
DIN EN 60068-2-27, 100 g, 6 ms |
Vibration resistance |
DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz |
許可和認(rèn)證: |
UL approval |
cULus Listed, General Purpose, Class 2 Power Source |
周圍環(huán)境: |
Operating temperature |
-30 ... 55 °C (-22 ... 131 °F) |
Storage temperature |
-30 ... 70 °C (-22 ... 158 °F) |
機(jī)械特性: |
Material |
|
|
Combination 1 |
housing: powder coated aluminum
flange: aluminum
shaft: stainless steel |
Mass |
approx. 600 g (combination 1) |
Rotational speed |
max. 6000 min -1 |
Moment of inertia |
30 gcm2 |
Starting torque |
≤ 3 Ncm (version without shaft seal) |
Shaft load |
|
|
Axial |
40 N |
|
Radial |
110 N |
與危險(xiǎn)區(qū)域有關(guān)的應(yīng)用數(shù)據(jù): |
EC-Type Examination Certificate |
|
|
Group, category, type of protection |
II 3G Ex nA IIB T4 Gc
II 3D Ex tc IIIC T120°C Dc IP64 |
Directive conformity |
|
|
Directive 94/9/EC |
EN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2009 |